Lutron AQ-9901SD Air Quality Meter

Air Quality Meter
Model: AQ-9901SD
Lutron – Taiwan

Achieve Precision and Comprehensive Data Logging with a Multi-Function Air Quality Meter

The AQ-9901SD Air Quality Meter provides accurate and reliable measurements of CO2, CO, O2, humidity, dew point, and temperature, with real-time data logging capabilities, making it an essential tool for various industrial and environmental applications.

Description

Exceptional Features of the AQ-9901SD:

1. Real-Time Data Logger: Saves measuring data along with time information (year, month, date, hour, minute, second) into the SD memory card, enabling easy download to Excel for further data analysis without extra software.

2. Multi-Function Measurement: Measures CO2 (carbon dioxide), CO (carbon monoxide), O2 (oxygen), humidity, dew point temperature, and ambient temperature, providing comprehensive air quality analysis.

3. High Accuracy and Resolution: Features high accuracy (e.g., ±40 ppm for CO2) and resolution (e.g., 0.1% for O2), ensuring precise and repeatable measurements.

4. User-Friendly Design: Equipped with a large LCD display with green backlight for easy reading, and user-friendly controls including data hold, peak hold, max/min functions, and alarm settings.

5. Advanced Connectivity: Includes RS232/USB computer interface for data output, enhancing data management and integration with other systems.

Technical Specifications:

– Display: 

 – Type: Large dot-matrix LCD with green backlight (ON/OFF)
  – Size: 52 mm x 38 mm

– Measurement Functions:

  – CO2 (Carbon Dioxide):

   – Range: 0 to 4,000 ppm
   – Resolution: 1 ppm
    – Accuracy: ±40 ppm (≤1,000 ppm), ±(50 ppm + 3% of reading) (1,000-3,000 ppm), reference only (>3,000 ppm)

  – CO (Carbon Monoxide):

   – Range: 0 to 1,000 ppm
   – Resolution: 1 ppm
   – Accuracy: ±(5% + 2 ppm)
   – Response Time: <30 seconds
   – Sensitivity Drift: <5% per year

  – O2 (Oxygen in Air):

   – Range: 0 to 30% O2
   – Resolution: 0.1% O2
   – Accuracy: ±(1% reading + 0.2% O2)
   – Response Time: ≤15 seconds to 90% reading value

  – Humidity:

   – Range: 10 to 95% RH
   – Resolution: 0.1% RH
   – Accuracy: ±(3% reading + 1% RH) (≥70% RH), ±3% RH (<70% RH)

  – Dew Point Temperature:

   – Range: -25.3 to 48.9℃
   – Resolution: 0.1℃
   – Accuracy: Calculated from humidity/temperature measurement

  – Temperature:

   – Range: 0 to 50℃, 32 to 122℉
   – Resolution: 0.1℃
   – Accuracy: ±0.8℃, ±1.5℉

  – Wet Bulb Temperature:

   – Range: -21.6 to 50.0℃
   – Resolution: 0.1℃
    – Accuracy: Calculated from humidity/temperature measurement

Data Logger:

 – Automatic: 2 to 3600 seconds
  – Manual: Push the data logger button once to save data

SD Card Capacity: 1 GB to 16 GB

Power Supply: 

 – DC 1.5V batteries (UM3, AA) x 6 PCs or DC 9V adapter (optional)
 – Power Consumption: 
 – Normal operation (without SD card save data and LCD backlight OFF): Approx. DC 136.5 mA
 – With SD card save data and LCD backlight OFF: Approx. DC 166 mA

Operating Environment:

 – Temperature: 0 to 50℃
  – Humidity: Less than 80% RH

Dimensions: 

 – Main Instrument: 177 x 68 x 45 mm
 – CO2/Humidity Probe: 197 mm length
 – O2 Probe: 150 x 38 x 38 mm
  – CO Probe: 150 x 38 x 38 mm

Weight: 350 g (0.77 lb)

Accessories Included:

– Instruction Manual: 1 PC
– Hard Carrying Case (CA-08): 1 PC
– CO2/Humidity Probe: 1 PC
– O2 Probe: 1 PC
– CO Probe: 1 PC

Optional Accessories:

– SD Memory Card (2 GB)
– AC to DC 9V Adapter
– USB Cable (USB-01)
– RS232 Cable (UPCB-02)
– Data Acquisition Software (SW-U801-WIN)

Advanced Features:

Microprocessor Circuit: Ensures high accuracy and reliability.

Auto/Manual Data Logging: Enhances data management and analysis capabilities.

Multiple Sensor Compatibility: Provides flexibility for various air quality parameters.

RS232/USB Interface: Enhances data management and integration with computer systems.

Alarm Setting: Alerts with beeper sound output for user-defined thresholds.

Complete Set: Includes four probes and a hard carrying case for convenience and protection.

Invest in the AQ-9901SD Air Quality Meter for precise and reliable air quality measurements with real-time data logging, ensuring high performance and versatility in various industrial and environmental applications.

Specifications
Circuit Custom one-chip of microprocessor LSI
circuit.
Display LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF )
Measurement CO2 (Carbon dioxide )
CO ( Carbon monoxide )
O2 ( Oxygen in air )
Humidity
Dew point Temp., Wet bulb Temp.
Temperature
Sensor structure CO2 NDIR * Nondispersive infrared sensor
Humidity Precision capacitance sensor
O2 Galvanic cell type
CO Galvanic cell type
Temp. Precision thermistor
Data logger Sampling Time Setting range Auto 2 sec to 8 hour 59 min. 59 sec.
@ Sampling time can set to 1 second, but memory data may loss.
Manual Push the data logger button once will save data one time.
@ Set the sampling time to 0 second.
@ Manual mode, can also select the1 to 99 position ( Location ) no.
Data error no. 0.1% of total saved data max.
Memory Card SD memory card. 1 GB to 16 GB
Advanced setting * SD memory card Format
* Set clock time
* Set sampling time
* Auto power OFF management
* Set beep Sound ON/OFF
* Decimal point of SD card setting
* Temp. unit setting
* Alarm value setting
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Sampling Time of Display Approx. 1 second.
Data Output RS 232/USB PC computer interface.
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
* Connect the optional USB cable
USB-01 will get the USB plug.
Power Supply * AAlkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.
* ADC 9V adapter input. ( AC/DC power adapter is optional ).
Power Current CO2 measure-ment
Normal operation ( w/o SD card save data and LCD Backlight is OFF) : Approx. DC 136.5 mA.
When SD card save the data and LCD Backlight is OFF) : Approx. DC 166 mA.
Humidity measure-ment
Normal operation ( w/o SD card save data and LCD Backlight is OFF) : Approx. DC 10.5 mA.
When SD card save the data and LCD Backlight is OFF) : Approx. DC 40 mA.
O2 or CO measure-ment
Normal operation ( w/o SD card save data and LCD Backlight is OFF) : Approx. DC 12.5 mA.
When SD card save the data and LCD Backlight is OFF) : Approx. DC 42.5 mA.
* AIf LCD backlight on, the power consumption will increase approx. 12 mA.
Operatin Temperature 0 to 50℃. (32 to 122℉).
Operating Humidity Less than 80% R.H.
Weight 350 g/0.77 LB.
Dimension Meter 177 x 68 x 45 mm
Humidity probe 197 mm in length.
CO2 probe 190 x 38 x 28 mm
O2 probe 150 x 38 x 38 mm
CO probe 150 x 38 x 38 mm
Unit /
CO2 Sensor Structure /
Response Time for CO2 measurement /
Temperature Compensation /
Data error no 0.1% of total saved data max.
Update Time of Display /
Over-range /
Accessories Included Instruction manual:1 PC
Hard carrying case, CA-08:1 PC
CO2 probe:1 PC
Humidity probe: 1 PC
O2 probe: 1 PC
CO probe: 1 PC
Optional Accessories SD memory card ( 2 GB )
AC to DC 9V adapter.
USB cable, USB-01.
RS232 cable, UPCB-02.
Data Acquisition software, SW-U801-WIN.
About brand
Lutron Electronic Enterprise (路昌電子企業股份有限公司) was established in 1976 and has been the Taiwan's leading manufacturer in the fields of Test & Measurement Instruments for more than 40 years. Nowadays, there are about 120 employees in our company, and the factory's building size is around 6,410 square meters / 69,000 feet.
Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.