Lutron PM-1064SD Air Quality Monitor in Bangladesh rotexlab

Lutron PM-1064SD Air Quality Monitor & Recorder 5 in 1

Achieve Precision and Comprehensive Data Logging with a Professional Air Quality Monitor

The PM-1064SD Air Quality Monitor/Recorder provides accurate and reliable measurements of PM2.5, CO2, humidity, temperature, and barometric pressure, with real-time data logging capabilities, making it an essential tool for various industrial, environmental, and HVAC applications.

Measuring Parameters:

* PM2.5:
* CO2 (Carbon Dioxide)
* Humidity
* Temperature
* Barometric Pressure

Exceptional Features of the AQ-9901SD

1. Multi-Parameter Measurement: Measures PM2.5, CO2, humidity, temperature, and barometric pressure, providing comprehensive air quality analysis.

2. Real-Time Data Logger: Saves measuring data along with time information (year, month, date, hour, minute, second) into the SD memory card, enabling easy download to Excel for further data analysis without extra software.

3. High Accuracy and Resolution: Features high accuracy with a wide measurement range, ensuring precise and repeatable measurements.

4. User-Friendly Design: Equipped with a large dot-matrix LCD display with backlight for easy reading, data hold function, and memory recall for maximum and minimum values.

5. Advanced Connectivity: Includes RS232/USB computer interface for data output, enhancing data management and integration with other systems.

6. Durable and Portable: Constructed with a robust housing and supplied with a hard carrying case, making it easy to carry and durable for long-lasting use.

Technical Specification & Model Options

– Display:

– Type: Dot-matrix backlit LCD

– Size: 55.4 x 72.9 mm (2.18 x 2.87 inches)

– Measurement Functions:

– PM2.5:

– Range: 0 to 250 µg/m³

– Resolution: 1 µg/m³

– Accuracy: ±(10% reading + 20 µg/m³)

– CO2 (Carbon Dioxide):

– Range: 0 to 10,000 ppm

– Resolution: 1 ppm

– Accuracy:

– ±40 ppm (≤ 1,000 ppm)

– ±(50 ppm + 3% of reading) (1,000-3,000 ppm)

– ±(50 ppm + 5% of reading) (> 3,000 ppm)

– Repeatability: ±20 ppm

– Humidity:

– Range: 5% to 95% RH

– Resolution: 0.1% RH

– Accuracy:

– <70% RH: ±3% RH

– ≥70% RH: ±(4% reading + 1% RH)

– Temperature:

– Range: 0 to 50℃ (32 to 122℉)

– Resolution: 0.1℃

– Accuracy: ±0.8℃, ±1.5℉

– Barometric Pressure:

– Range:

– 10.0 to 999.9 hPa, resolution: 0.1 hPa, accuracy: ±1.5 hPa

– 1000 to 1100 hPa, resolution: 1 hPa, accuracy: ±2 hPa

– 7.5 to 825.0 mmHg, resolution: 0.1 mmHg, accuracy: ±1.2 mmHg

– 0.29 to 32.48 inHg, resolution: 0.01 inHg, accuracy: ±0.05 inHg

– Data Logger:

– Automatic: Sampling time can be set from 1 second to 3600 seconds

– Manual: Push the data logger button once to save data one time

– SD Card Capacity: 1 GB to 32 GB

– Power Supply:

– DC 1.5V AA (UM3) batteries x 6 PCs

– AC to DC 9V power adapter

– Power Consumption:

– Approx. DC 135 mA

– Backlight ON: Approx. DC 150 mA

– Operating Environment:

– Temperature: 0 to 50℃

– Humidity: Less than 80% RH

– Dimensions:

164 x 93 x 72 mm (6.5 x 3.7 x 2.8 inches)

– Weight: 385 g (0.85 lb)

Accessories Included:

– Instruction Manual: 1 PC

– AC to DC 9V Power Adapter: 1 PC

Back to Top